Modular IVF OT Specification

  • Temperature Range
  • 18C to 25C (adjustable)
  • Height
  • Standard 8-10 ft (customizable)
  • Suitable For
  • IVF Procedures, Embryology Labs, ART Centers
  • Material
  • Stainless Steel / PPGI/ Glass
  • Automation Grade
  • Semi-automatic/Fully automatic (available as per requirement)
  • Power
  • Standard 220-240V (customizable)
  • Properties
  • Antimicrobial, Fire Retardant, Seamless finish, Smooth corners, Easy to clean
  • Accuracy
  • 1% (for HVAC and controls)
  • Use
  • Creation of controlled and sterile environment for IVF procedures
  • Display Type
  • Digital/Touchscreen (as per option)
  • Dimension (L*W*H)
  • Customized as per site requirements
  • Storage Capacity
  • Custom modular furniture and storage options
  • Color Code
  • Custom color options available (as per client requirement)
  • Application
  • IVF Operating Theatre, Assisted Reproductive Technology Laboratories, Medical Facilities
  • Function
  • Modular cleanroom functionality for IVF procedures
  • Humidity Range
  • 30% - 70% RH
  • Frequency
  • 50/60 Hz
  • Shape
  • Rectangular (customizable)
  • Weight
  • Depends on size & configuration
  • Product Type
  • Modular IVF OT
  • Treatment Type
  • Assisted Reproductive Technology/In-Vitro Fertilization
  • Phase
  • Single/Three Phase
  • Power Source
  • Electric
  • Voltage
  • 220-240 V AC
  • Display
  • LED touch panel (optional integrations available)
  • Operating Light Integration
  • Ceiling or wall-mounted LED OT lights possible
  • Exhaust System
  • Dedicated exhaust with HEPA filtration
  • Utility Provisions
  • Integrated medical gas panels, electrical trunking, IT/data points
  • Windows
  • Double-glazed flush-view windows, integrated blinds possible
  • Wall Paneling
  • Double skin modular PUF/Glass panels (40-60mm thick)
  • Lighting
  • LED shadowless, 600-1000 lux at working plane
  • Air Changes per Hour
  • Minimum 20-25 ACH for class 7 cleanroom
  • Noise Level
  • Less than 60 dB(A) inside OT
  • Installation Time
  • Rapid installation, less than 4 weeks for standard designs
  • Flooring
  • Conductive or anti-microbial PVC/vinyl seamless flooring
  • Air Filtration
  • HEPA 0.3 micron, 99.97% efficiency
  • Door Type
  • Hermetically sealed sliding or swing doors
  • Ceiling
  • Seamless false ceiling, powder-coated finish
  • Control System
  • Microprocessor-based HVAC environmental control
 

Modular IVF OT Trade Information

  • Minimum Order Quantity
  • 1 Set
  • FOB Port
  • Noida
  • Payment Terms
  • Cash on Delivery (COD), Cash Advance (CA), Cash in Advance (CID), Cheque
  • Supply Ability
  • 100 Sets Per Month
  • Delivery Time
  • 1
  • Sample Available
  • Yes
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • standard
  • Main Domestic Market
  • All India
 

About Modular IVF OT

Modular IVF Lab & OT

As the Modular ivf lab and modular ivf operation theatre manufacturer, Modular Healthcare System have been serving the medical industry for years by giving a tough competition to other healthcare systems providers.

Product details

Colour

Customised

Fixing Time

7Days

Warrenty

No

Service Location/City

India

Surface Treatment

Paint Coated

Built Type

Modular

Material

Stainless Steel



Sterile and Seamless Panel Construction

Double-skin PUF or glass panels (4060mm thick) create seamless, antimicrobial, and fire retardant wall surfaces. Their smooth corners and easy-to-clean interfaces enable stringent hygiene standards suitable for IVF procedures, preventing particulate accumulation and cross-contamination.


Integrated Environmental and Process Control

A microprocessor-based HVAC system precisely regulates temperature (1825C), humidity (3070% RH), and positive pressure. Combined with high-efficiency HEPA filtration and 2025 air changes per hour, the OT maintains cleanroom standards (class 7), dramatically reducing risks of contamination during sensitive ART procedures.


Optimized Lighting and Visibility

Ceiling or wall-mounted LED OT lights deliver shadowless 6001000 lux at the working plane, enhancing visibility for IVF tasks. Double-glazed flush windows with integrated blinds ensure privacy while maintaining clear observation lines for staff safety and workflow efficiency.


Rapid Custom Installation and Flexible Design

Delivered as modular solutions, these IVFs OTs enable rapid installation (typically under 4 weeks for standard configurations) with tailor-made furniture, storage, dimensioning, and color coding available to suit unique facility needs and branding, maximising operational uptime with minimal site disruption.

FAQs of Modular IVF OT:


Q: How is air purity and contamination control maintained in a Modular IVF OT?

A: The OT uses HEPA filters (0.3 micron, 99.97% efficiency) and achieves 2025 air changes per hour, meeting class 7 cleanroom standards. Combined with a dedicated exhaust and seamless, antimicrobial surfaces, this setup keeps the operating space sterile and free of harmful particulates.

Q: What is the installation timeline for the modular IVF operating theatre?

A: Rapid installation is ensured, with standard modular designs typically completed in less than four weeks. Custom configurations can be delivered based on specific site requirements, minimizing operational downtime for healthcare facilities.

Q: Where are modular IVF OTs most suitable for use?

A: These OTs are designed for IVF operating theatres, embryology labs, ART centers, and medical facilities requiring strict sterility and environmental control for assisted reproductive technologies. Their modularity makes them suitable for new builds or upgrades in hospitals and clinics.

Q: What are the benefits of seamless wall and floor paneling in IVF labs?

A: Seamless double-skin PUF/glass panels and antimicrobial vinyl/PVC flooring prevent microbial growth, reduce cleaning frequency, and eliminate cracks where contaminants can accumulate. They contribute significantly to maintaining a consistently sterile environment.

Q: How is environment management automated inside the IVF OT?

A: A microprocessor-based control system manages HVAC functions, regulating temperature (1825C), humidity (3070% RH), and airflow patterns for optimal conditions. Optional digital touch panels provide intuitive monitoring and adjustments as needed.

Q: What customization options are available for modular IVF OTs?

A: Clients can choose from custom dimensions, color codes, door types (hermetic sliding/swing), display systems (digital/touchscreen), and functional modular furniture and storage. Lighting, power supply, and automation grades can also be selected according to operational preferences.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Surgical Scrub Stations Category

WIRELESS Nurse Call System

WIRELESS Nurse Call System

Price 32000.0 INR / Number

Minimum Order Quantity : 1 Number

Use : Hospital

Application : Medical

Portable : Yes

Product Type : Medical Equipment